AT-924 UV Cure Epoxy System Data

Optimum cure wavelength

313 nm (Hg emission line)
Hg vapor lamp most suitable for cure, long wave UV OK

Viscosity data (measured using Brookfield viscometer)

Temperature

RPM

Viscosity (cP)

Additives

28.0

60

370

none

24.0

60

550

none

23.0

60

1680

100 cm3 additive/liter

23.0

12

39900

350 cm3 additive/liter

23.0

6

72500

350 cm3 additive/liter

23.0

3

138000

350 cm3 additive/liter

23.0

1.5

260000

350 cm3 additive/liter

Material is extremely thixotropic with additives.

 

Handling and Processing Instructions

General Requirements

bullet

 Light Sensitive Material - Avoid Unintentional Exposure to Light.

bullet

 Process at 70° C - Must be Thoroughly Mixed Before Processing. Store at 70° F to Maintain Mixture Homogeneity. If Separation Occurs (white flakes in mixture), Heat to 70° C and Tumble to Mix.

bullet

 Material is Sensitive to Freons - Do Not Expose Cured Coatings to Freons.

Health Information

bullet

 Mixture is Irritant.

bullet

 Avoid Eye and Skin Contact - Wear Protective Clothing.

MSDS Request

Shelf Life

bullet

 One year unless exposed to heat or light.

Equipment Requirements

bullet

 UV Light Source - Fusion UV Curing Systems (301/251-0300) Model F300 or Equivalent.

bullet

 Protected Enclosure for UV Exposures.

bullet

 Spray Gun - BINKS Model 115 with 78S tip and 8 oz fluid cup or Equivalent. Propel with Nitrogen.

bullet

 Clean Bench or Fume Hood to Control Dust and Fumes.

bullet

 Antistatic Materials for Handling Electronic Components.

Spray Coating Procedures

bullet

 Filter AT-924 Epoxy at 70° C into Clean Spray Gun Reservoir.

bullet

 Surface Preparation - Surfaces to be Coated Must be Contaminant Free. Clean with an Appropriate Solvent. Where Possible, Etching or Abrading Surface Will Promote Adhesion.

bullet

 Spray Coating - Spray with Epoxy at 70° C with 30 psi Nitrogen. Where Possible, Spray onto Warm Substrate for Best Results. Avoid Exposure of Coated Substrate to Dust or Other Contaminants Prior to UV Cure.

bullet

 UV Cure - Expose to High Intensity UV Light Source for 60 Seconds. Light Must Reach into All Coated Areas - Rotate Substrate or Expose in a Reflective Enclosure.

bullet

 Postcure - Expose UV Cured Coating at 70° C for 2-4 Hours in a Clean Oven to Complete Cure. May be postcured at 125° C for higher temperature applications.

 

 